Related Experiment Video
Updated: Apr 28, 2026

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
Reevaluating reference ranges of oxygen saturation for healthy full-term neonates using pulse oximetry
Ying-Chun Lu1, Chih-Chien Wang2, Chuen-Ming Lee3
1Department of Pediatrics, Tri-Service General Hospital, National Defense Medical Center, Taipei, Taiwan; Department of Chemistry, Fu Jen Catholic University, New Taipei City, Taiwan; Graduate Institute of Basic Medicine, Fu Jen Catholic University, New Taipei City, Taiwan.
Background:
We compared our clinical experience with currently available reference oxygen saturation level (SpO(2)) values from the American Academy of Pediatrics/American Heart Association (AAP/AHA) neonatal resuscitation program guidelines.
Methods:
We enrolled 145 healthy full-term neonates; infants showing respiratory distress and those with serious congenital anomalies were excluded. SpO(2) values at every 1 minute until 10 minutes after birth were measured and recorded. Infants were classified into the cesarean section (CS) and normal spontaneous delivery (NSD) groups for evaluating differences. The 10(th) percentiles of SpO(2) at each minute were used as the lower limits of normal oxygen saturation, and these were compared with the lowest target values recommended in the AAP/AHA guidelines.
Results:
Overall, 130 vigorous full-term neonates (median gestational age: 38 5/7 weeks; body weight at birth: 2405-3960 g) were analyzed. The median SpO(2) were 67% and 89% at the 1(st) and 4(th) minute, respectively. On average, SpO(2) values reached >90% at the 5(th) minute. No statistical differences were noted in the SpO(2) values between the CS and NSD groups after 5 minutes; however, a trend of higher SpO(2) was observed in the NSD group. We noted a gradually increasing trend for SpO(2) values over time, similar to that noted in the AAP/AHA guidelines. However, SpO(2) values at the 10(th) percentiles of each minute within the first 5 minutes in our study were equal to or significantly lower than those in the AAP/AHA guidelines; moreover, at the 10(th) minute, SpO(2) values at the 10(th) percentiles were significantly higher than those in the guidelines.
Conclusion:
The delivery modes did not affect the SpO(2) values of full-term healthy neonates. Discrepancies in SpO(2) changes in full-term neonates not requiring resuscitation between this study and the AAP/AHA guidelines were significant. SpO(2) ranges for each time point within the first 10 minutes after birth should therefore be reevaluated locally.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Transport in the Blood