Related Experiment Video
Updated: Apr 28, 2026

Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves
Published on: October 17, 2013
What type of valve is most appropriate for osteogenesis imperfecta patients?
Georgios Dimitrakakis1, Dimitrios Challoumas2, Ulrich Otto von Oppell2
1Department of Cardiothoracic Surgery, University Hospital of Wales, Heath Park Campus, Cardiff, UK gdimitrakakis@yahoo.com.
Abstract:
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was in osteogenesis imperfecta (OI) patients with valve disease undergoing valve replacement which type of valve (bioprosthetic or mechanical) is most appropriate in terms of safety, complications and survival. Altogether more than 77 papers were found as a result of the reported search, of which 43 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Previous review articles have presented case reports up to 2009. As all published data are based on case reports, we conducted a more detailed analysis that included the aforementioned series, reports that were missed prior to 2009 and all published data from 2009 to October 2013. Our analysis identified 43 OI patients. Mechanical valves were used in the majority of cases (31 patients), bioprosthetic valves in 10 patients and homografts in 2 patients. We conclude that based on the best available evidence, it appears that bioprosthetic valves have had better outcomes (mortality rate 10%) and a lower valve-related complication rate (0%) compared with mechanical valves (mortality rate 16.1%, complication rate 16.1%), even though differences were not statistically significant. Although the existing evidence is solely based on case reports of a relatively small number, we would suggest the use of bioprosthetic valves in OI patients with valve disease, as they appear to be safer according to our analysis. Moreover, considering the surgical difficulties related to the friability and weakness of the tissues in terms of suture lines and implantation of the valve as well as the high risk of perioperative bleeding which can be related to tissue friability, capillary fragility and platelet dysfunction followed by the risk of major traumatic fractures and a possible risk of aortic dissection in the future, the bioprosthetic valves seem to be safer taking into account the avoidance of lifelong anticoagulation and its secondary bleeding complications.
More Related Videos
12:17Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Mitral Stenosis III: Medical Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Aortic Regurgitation III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse I: Introduction
Mitral Stenosis I: Introduction