Related Experiment Video
Updated: Apr 28, 2026

Quantitatively Measuring In situ Flows using a Self-Contained Underwater Velocimetry Apparatus SCUVA
Published on: October 31, 2011
Doppler detection in Ama divers of Japan
Frédéric Lemaître1, Kiyotaka Kohshi2, Hideki Tamaki2
1Centre d'Etudes des Transformations des Activités Physiques et Sportives (CETAPS, EA 3832), Faculté des Sciences du Sport, Université de Rouen, France (Drs Lemaître and Costalat); Association pour la Recherche sur l'Apnée et les Activités Subaquatiques (APRAAS; Drs Lemaître and Gardette).
Objective:
Symptoms consistent with neurological decompression sickness (DCS) in commercial breath-hold (Ama) divers has been reported from a few districts of Japan. The aim of this study was to detect circulating intravascular bubbles after repetitive breath-hold diving in a local area where DCS has been reported in Ama divers.
Methods:
The participants were 12 partially assisted (descent using weights) male Ama divers. The equipment (AQUALAB system) consisted of continuous-wave Doppler with a 5-MHz frequency, and the Doppler probe was placed in the precordial site with the ultrasonic wave directed into the pulmonary infundibulum. We carried out continuous monitoring for 10 minutes at the end of the series of repetitive dives, and the recordings were made on numerical tracks and graded in a blind manner by 2 experienced investigators, according to the Spencer Doppler code.
Results:
Depths and number of dives were 8 to 20 m and 75 to 131 times. Mean diving duration and surface interval were 64 ± 12 seconds and 48 ± 8 seconds, respectively (mean ± SD). We detected the lowest grade of intravascular bubbles (Spencer's grade I) in an Ama diver whose mean surface interval was only 35.2 ± 6.2 seconds. His mean descending, bottom, and ascending times were 10.4 ± 1.6 seconds, 39.2 ± 8 seconds, and 18.2 ± 3.0 seconds, respectively, over the course of 99 dives.
Conclusions:
Intravascular bubbles may be formed after repetitive breath-hold dives with short surface intervals or after a long breath-holding session in Ama divers. Symptoms consistent with neurological accidents in repetitive breath-hold diving may be caused in part by the intravascular presence of bubbles, indicating the need for safety procedures.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Doppler Effect - II
Doppler Effect - I
Buoyancy
Buoyancy and Stability for Submerged and Floating Bodies

