Related Experiment Video
Updated: Apr 28, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Comparison of diffusion-weighted imaging and contrast-enhanced T1-weighted imaging on a single baseline MRI for
Chung-Ping Lo1, Hung-Wen Kao, Shao-Yuan Chen
1Department of Radiology, Taichung Tzuchi Hospital, The Buddhist Tzuchi Medical Foundation, No 66, Sec 1, Fongsing Road, Taichung Tanzih District, 427, Taiwan. rain2343@ms22.hinet.net.
Background:
The 2010 Revisions to the McDonald Criteria have established that dissemination in time (DIT) of multiple sclerosis (MS) can be demonstrated by simultaneous presence of asymptomatic gadolinium-enhancing and nonenhancing lesions on a single magnetic resonance imaging (MRI). However, gadolinium-based contrast agents (GBCAs) have contraindications. Diffusion-weighted imaging (DWI) can detect diffusion alterations in active inflammatory lesions. The purpose of this study was to investigate if DWI can be an alternative to contrast-enhanced T1-weighted imaging (CE T1WI) for demonstrating DIT in MS.
Methods:
We selected patients with clinically definite MS and evaluated their baseline brain MRI. Asymptomatic lesions were identified as either hyperintense or nonhyperintense on DWI and enhancing or nonenhancing on CE T1WI. Fisher's exact test was performed to determine whether the hyperintensity on DWI was related to the enhancement on CE T1WI (P < 0.05). The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of the DWI to predict lesion enhancement were calculated.
Results:
Twenty-two patients with 384 demyelinating lesions that were hyperintense on T2-weighted imaging and more than 3 mm in size were recruited. The diffusion hyperintensity and lesion enhancement were significantly correlated (P <0.001). The sensitivity, specificity, PPV, NPV and accuracy were 100%, 67.9%, 32.3%, 100% and 72.1%, respectively.
Conclusions:
A hyperintense DWI finding does not necessarily overlap with contrast enhancement. There are many false positives, possibly representing other stages of lesion development. Although DWI may not replace CE T1WI imaging to demonstrate DIT due to the low PPV, it may serve as a screening MRI sequence where the use of GBCAs is a concern.
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Imaging Studies for Cardiovascular System IV: CMRI

