Related Experiment Video
Updated: Apr 28, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Which are the best VO2 sampling intervals to characterize low to severe swimming intensities?
K de Jesus1, L Guidetti2, K de Jesus1
1Centre of Research, Education, -Innovation and Intervention in Sport, Faculty of Sport, -University of Porto, Porto, Portugal.
Abstract:
Cardiorespiratory response in swimming has been used to better understand aerobic performance, especially by assessing oxygen uptake (VO2). The current study aimed to compare different VO2 time-averaging intervals throughout low to severe swimming intensities, hypothesizing that VO2 values are similar for different time averages at low to moderate and heavy swimming intensities, but not for the severe domain. 20 male trained swimmers completed an incremental protocol of 7×200 m until exhaustion (0.05 m/s increments and 30 s intervals). VO2 was measured by a portable gas analyser connected to a snorkel system. 6 time average intervals (breath-by-breath, 5, 10, 15, 20 and 30 s) were compared for all the protocol steps. Breath-by-breath and 5 s average exhibited higher VO2 values than averages≥10 s for all swimming intensities (P≤0.02; partial η(2)≤0.28). VO2 values did not differ between 10, 15, 20 and 30 s averages throughout the incremental protocol (P>0.05; partial η(2)≤0.05). Furthermore, 10 and 15 s averages showed the lowest VO2 mean difference (0.19 mL( · )kg(-1 · )min(-1)). For the 6 time average intervals analysed, 10 and 15 s averages were those that showed the lowest changes on VO2 values. We recommended the use of 10 and 15 s time averaging intervals to determine relevant respiratory gas exchange parameters along a large spectrum of swimming intensities.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...

