Association between prophylactic implantable cardioverter-defibrillators and survival in patients with left
Sana M Al-Khatib1, Anne S Hellkamp2, Gregg C Fonarow3
1Duke Clinical Research Institute, Department of Medicine, Duke University Medical Center, Durham, North Carolina3Division of Cardiology, Department of Medicine, Duke University Medical Center, Durham, North Carolina.
Importance:
Clinical trials of prophylactic implantable cardioverter-defibrillators (ICDs) have included a minority of patients with a left ventricular ejection fraction (LVEF) between 30% and 35%. Because a large number of ICDs in the United States are implanted in such patients, it is important to study survival associated with this therapy.
Objective:
To characterize patients with LVEF between 30% and 35% and compare the survival of those with and without ICDs.
Design, Setting, And Participants:
Retrospective cohort study of Medicare beneficiaries in the National Cardiovascular Data Registry ICD registry (January 1, 2006, through December 31, 2007) with an LVEF between 30% and 35% who received an ICD during a heart failure hospitalization and similar patients in the Get With The Guidelines-Heart Failure (GWTG-HF) database (January 1, 2005, through December 31, 2009) with no ICD. The analysis was repeated in patients with an LVEF less than 30%. There were 3120 patients with an LVEF between 30% and 35% (816 in matched cohorts) and 4578 with an LVEF less than 30% (2176 in matched cohorts). Propensity score matching and Cox models were applied.
Main Outcomes And Measures:
The primary outcome was all-cause mortality; data were obtained from Medicare claims through December 31, 2011.
Results:
There were no significant differences in the baseline characteristics of the matched groups (n = 408 for both groups). Among patients with an LVEF between 30% and 35%, there were 248 deaths in the ICD Registry group, within a median follow-up of 4.4 years (interquartile range, 2.7-4.9) and 249 deaths in the GWTG HF group, within a median follow-up of 2.9 years (interquartile range, 2.1-4.4). The risk of all-cause mortality in patients with an LVEF between 30% and 35% and an ICD was significantly lower than that in matched patients without an ICD (3-year mortality rates: 51.4% vs 55.0%; hazard ratio, 0.83 [95% CI, 0.69-0.99]; P = .04). Presence of an ICD also was associated with better survival in patients with an LVEF less than 30% (3-year mortality rates: 45.0% vs 57.6%; 634 and 660 total deaths; hazard ratio, 0.72 [95% CI, 0.65-0.81]; P < .001) (P = .20 for interaction).
Conclusions And Relevance:
Among Medicare beneficiaries hospitalized for heart failure and with an LVEF between 30% and 35% and less than 30%, survival at 3 years was better in patients who received a prophylactic ICD than in comparable patients with no ICD. These findings support guideline recommendations to implant prophylactic ICDs in eligible patients with an LVEF of 35% or less.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Heart Failure VI: Adjunct Therapies
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Cardiopulmonary Resuscitation III: AED Use
Heart Failure V: Medical Management