Four homing pigeons were exposed to concurrent variable-interval 40-s variable-interval 120-s schedules of reinforcement with changeover delays of five durations (0, 1, 2, 4, and 8 s). The changeover delays of non-zero durations were presented with and without blackout of the experimental chamber in different conditions. Blackout eliminated or strongly reduced responding during the changeover delay. It decreased the run length of responding after the changeover delay in the variable-interval 120-s component, but it had no systematic effects on the run length after the changeover delay in the variable-interval 40-s component. In both components, the run lengths after the changeover delay increased with the duration of the delay. Blackout increased deviations from response matching, computed from measures of responding after the changeover delay. The deviations increased with the duration of the changeover delay. The reults suggest that the finding of overmatching with procedures other than the changeover delay does not depend exclusively on the absence of responding in the interval that elapses between initiation of the change to an alternative and the first response eligible for reinforcement.
Related Concept Videos
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Fast Decoupled and DC Powerflow