A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Positron emission tomography alone, positron emission tomography-computed tomography and computed tomography in
Yi Xiao1, Jia Wei1, Yicheng Zhang1
1Department of Hematology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China.
Introduction:
The aim of the study was to assess systematically the accuracies of positron emission tomography (PET), PET/computed tomography (CT), and CT in diagnosing recurrent cervical cancer.
Material And Methods:
We searched for articles published from January 1980 to June 2013 using the following inclusion criteria: articles were reported in English; the use of PET, interpreted with or without the use of CT; use of CT to detect recurrent cervical cancer; and histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months. We extracted data to calculate sensitivity, specificity, summary receiver operating characteristic curves, and the area under the receiver operating characteristic curve (AUC) as well as test for heterogeneity.
Results:
In 23 included studies, PET had the highest pooled specificity at 92% (95% CI: 90-94), whereas PET/CT had the highest pooled sensitivity at 94% (95% CI: 90-97). The area under the curve (AUC) of PET alone, PET/CT, and CT were 0.9594, 0.9508, and 0.9363, respectively. Results of the pairwise comparison between each modality show that the specificity of PET was higher than that of PET/CT (p < 0.05). The difference in the pooled sensitivities and AUC of PET alone and PET/CT showed no statistical significance. No evidence of publication bias was found. However, evidence of heterogeneity was observed.
Conclusions:
The PET/CT may be a useful supplement to current surveillance techniques, particularly for patients with negative CT imaging. However, in terms of diagnostic accuracy, interpreted CT images may have limited additional value to PET in detecting recurrent cervical cancer.
More Related Videos
09:34Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...