Related Experiment Video
Updated: Apr 28, 2026

Knotless Independent Double-Row Repair and Biceps Augmentation for Anterosuperior Rotator Cuff Tears
Published on: January 23, 2026
Does transosseous-equivalent rotator cuff repair biomechanically provide a "self-reinforcement" effect compared with
Maxwell C Park1, Michelle H McGarry2, Robert C Gunzenhauser2
1Department of Orthopaedic Surgery, Southern California Permanente Medical Group, Woodland Hills, CA, USA.
Background:
Transosseous-equivalent (TOE) rotator cuff repair has been theorized to be "self-reinforcing" against potentially destructive and increasing tendon loads. The goal of this study was to biomechanically verify and characterize the effect of increasing tendon load on frictional resistance over a repaired footprint for single-row (SR) and TOE repair techniques.
Methods:
In 10 fresh frozen human shoulders, TOE and SR supraspinatus tendon repairs were performed in each specimen. For all repairs, a pressure sensor was secured at the tendon-footprint interface. The supraspinatus tendon was loaded with 0, 20, 40, 60, and 80 N at 0° and 30° abduction. Paired t tests and multivariate regression analyses were used for comparisons.
Results:
The SR repair had significant increases in footprint contact force, area, and pressure between each and all tendon-loading conditions (P < .05). The TOE repair similarly demonstrated increases in footprint contact force with increasing tendon load (P < .05). Comparing between repairs, TOE repair had more footprint contact force, area, pressure, and peak pressure at each load for both abduction angles (P < .05). With increasing load, the TOE repair had a significantly higher progression (slope) of footprint force and pressure compared with the SR repair.
Conclusions:
Self-reinforcing capacity in rotator cuff repair has been biomechanically characterized and verified. The TOE repair, with tendon-bridging sutures fixed medially and spanning the footprint, provides disproportionately more progressive footprint frictional resistance with increasing tendon loads compared with the SR repair secured over isolated fixation points. This self-reinforcing effect could help sustain structural integrity and potentially improve healing biology.
More Related Videos
06:41A Novel Arthroscopic Medial Knot-Tying Suture-Bridge Repair with Rip-Stop Technique for Rotator Cuff Tears
Published on: January 13, 2026
07:22Arthroscopic Management of Massive Irreparable Rotator Cuff Tears: Whole Rotator Cable Reconstruction Using Proximal Biceps Tendon Autograft
Published on: June 6, 2025