Effect of endodontic irrigants on microtensile bond strength to dentin after thermocycling and long-term water storage
Related Experiment Video
Updated: Apr 28, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Daniel Galafassi1, Vivian Colucci1, Doglas Cecchin2
1Department of Operative Dentistry, RibeirãoPreto School of Dentistry, University of São Paulo, RibeirãoPreto, Brazil.
Objective:
The bond strength of adhesives in irrigated dentin behaves differently over time. The aim of this study was to evaluate the influence of long-term water storage and thermocycling on the microtensile bond strength of adhesive systems to dentin irrigated with endodontic solutions.
Materials And Methods:
Sixty human molars were used after removal of the occlusal portion and exposure of the dentin by grinding. The specimens were irrigated with 2.5% NaOCl for 30 minutes and then 17% EDTA for 5 minutes and assigned to six groups according to the adhesive system (n=10): G1 and G2-Clearfil SE Bond; G3 and G4-Single Bond 2; and G5 and G6-XP Bond. The teeth were restored with composite and were subjected to water storage for different time periods. G1, G3 and G5 were stored for 24 h; G2, G4 and G6 were stored for 6 months and were subjected to thermocycling (12,000 cycles, 5°C to 55°C, 500 cycles per week for 6 months). After storage, the tooth/restoration assembly was sectioned to obtain four sticks of approximately 1 mm(2), for microtensile bond strength testing. The results were analyzed by two-way ANOVA and Tukey's test.
Results:
Significant differences were observed among the adhesives (p<0.01). No significant differences were observed in the microtensile bond strength between samples after 24 hours of storage without thermocycling and after 6-month storage with 12,000 cycles (p<0.05).
Conclusion:
The bond strengths of G5 and G6 after irrigation with 2.5% NaOCl and 17% EDTA were significantly different from those of other groups. Long-term water storage/thermocycling had no effect on bond strength to dentin.
More Related Videos
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
03:10Pilot In Vitro Study to Assess Cleaning Ability and Effects of Different Decontamination Methods on Implant Surfaces
Published on: November 21, 2025
Related Concept Videos
Testing Water Quality
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...