Related Experiment Video
Updated: Apr 28, 2026

Treating Surfaces with a Cold Atmospheric Pressure Plasma using the COST-Jet
Published on: November 2, 2020
Fundamental properties of a touchable high-power pulsed microplasma jet and its application as a
Takahiro Iwai1, Ken Kakegawa, Kensuke Okumura
1Department of Energy Sciences, Tokyo Institute of Technology, 4259 Nagatsuta, Midori-ku, Yokohama, Kanagawa, 226-8502, Japan.
Abstract:
Plasma-based ambient desorption/ionization mass spectrometry (ADI-MS) has attracted considerable attention in many fields because of its capacity for direct sample analyses. In this study, a high-power pulsed microplasma jet (HPPMJ) was developed and investigated as a new plasma desorption/ionization source. In an HPPMJ, a microhollow cathode discharge is generated in a small hole (500 µm in diameter) using a pulsed high-power supply. This system can realize a maximum power density of 5 × 10(8) W/cm(3). The measured electron number density, excitation temperature and afterglow gas temperature of the HPPMJ were 3.7 × 10(15) cm(-3), 7000 K at maximum and less than 60 °C, respectively, which demonstrate that the HPPMJ is a high-energy, high-density plasma source that is comparable with an argon inductively coupled plasma while maintaining a low gas temperature. The HPPMJ causes no observable damage to the target because of its low gas temperature and electrode configuration; thus, we can apply it directly to human skin. To demonstrate the analytical capacity of ADI-MS using an HPPMJ, the plasma was applied to direct solid sample analysis of the active ingredients in pharmaceutical tablets. Caffeine, acetaminophen, ethenzamide, isopropylantipyrine and ibuprofen were successfully detected. Application to living tissue was also demonstrated, and isopropylantipyrine on a finger was successfully analyzed without damaging the skin. The limits of detection (LODs) for caffeine, isopropylantipyrine and ethenzamide were calculated, and LODs at the picogram level were achieved. These results indicate the applicability of the HPPMJ for high-sensitivity analysis of materials on a heat-sensitive surface.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Overview