Related Experiment Video
Updated: Apr 28, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Stress Analysis on Single Cobalt/Chrome Prosthesis With a 15-mm Cantilever Placed Over 10/13/15-mm-length Implants: A
José Fábio Guastelli Gastaldo1, Angélica Castro Pimentel2, Maria Helena Gomes1
11 Department of Dental Prosthesis, University of São Paulo - USP, Sao Paulo, Brazil.
Abstract:
The aim of study was to assess the stress around 10/13/15-mm implants in the mandibular area with a 15-mm cantilevered acrylic-resin-coated prostheses following the application force, using the photoelasticity method. Three photoelastic mandibular models were created containing 10-, 13-, and 15-mm implants in length and 3.75 mm in diameter. The implants had bore internal hex connections and were placed parallel to the intermental region. Abutments with 1-mm high cuffs were placed over the implants, and a single cobalt/chrome metallic prosthesis with a 15-mm cantilever, coated with thermoplastic acrylic resin, was placed on top. Loads of 1.0 and 3.0 bars were applied, and the images were photographed and assessed by photoelasticity method. The greatest stress levels were observed for the 10-mm implants. The stress pattern was the same regardless of implant length; only the magnitude of the stress along the implant body revealed changes. Increased implant length played a role in reducing stress on the investigated area of the model, and the 15-mm implants exhibited the best performance in regard to stress distribution. The highest stress levels were found in the implants closest to the cantilever and the central implant. The longest implants were more favorable in regard to the stress distribution on the peri-implant support structures in the 15-mm cantilevered prosthesis under loads.
More Related Videos
Related Concept Videos
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Normal Strain under Axial Loading
Residual Stresses in Bending
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Eccentric Axial Loading in a Plane of Symmetry

