Related Experiment Video For 18F-fluorodeoxy glucose (FDG) positron emission tomography computed tomography
Updated: Jul 31, 2026

Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Thyroid incidentalomas discovered on positron emission tomography CT scanning - Malignancy rate and significance of
Aims:
Increasing use of 18F-Fluorodeoxy glucose (FDG) Positron Emission Tomography Computed Tomography (PET CT) has resulted in an increased frequency of incidentally discovered areas of focally increased FDG uptake within the thyroid gland - thyroid incidentalomas. We aimed to compare radiological characteristics of thyroid incidentalomas with cytology, histology and ultrasound findings.
Materials And Methods:
We examined all FDG PET CT scan reports for all patients undergoing this investigation over a 6 year period in a single tertiary cancer centre. All PET CT scans followed an agreed proforma allowing reports mentioning "thyroid" to be identified. Reports commenting on a positive finding within the thyroid gland were investigated further manually. Incidental mentions of thyroid with no underlying abnormality were discounted from analysis.
Results:
In the study period, 7221 patients underwent FDG PET CT scanning in our unit. Within this group 75 (1%) showed diffuse FDG uptake and 81 (1.1%) showed focal uptake (thyroid incidentalomas). Only 30 patients (37%) with incidentalomas had further investigation and malignancy rate was 23% (7/30). Median Standardised Uptake Values (SUV) in malignant lesions was 9.9 (range 3.5-17.8) whilst in benign lesions and diffuse lesions it was 5.4 (2.8-32) and 4.2 (2.1-25.6) respectively (p = 0.0013, Kruskal Wallis).
Conclusion:
There remains a need to develop a standardised approach to the investigation and management of thyroid incidentalomas discovered on FDG PET CT scanning. Up to 1 in 4 of these patients will harbour thyroid malignancy.
More Related Videos
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET