Related Experiment Video
Updated: Apr 28, 2026

A Microfluidic Flow Chamber Model for Platelet Transfusion and Hemostasis Measures Platelet Deposition and Fibrin Formation in Real-time
Published on: February 14, 2017
Repeated early hemofiltration filters clotting and heparin-induced thrombocytopenia in ICU
Sébastien Perbet1, Thomas Godet, Aurélien Lebreton
1CHU Clermont-Ferrand, General Intensive Care Unit, University Hospital Estaing, Clermont-Ferrand, France, sperbet@chu-clermontferrand.fr.
Repeated early hemofiltration filter clotting are real thrombotic events. Diagnosis of heparin-induced thrombocytopenia (HIT) in this setting in ICU remains difficult. We describe two cases of repeated early hemofiltration filters clotting in ICU and to evaluate their impact on the probability test 4T's score and diagnosis of HIT. Two patients undergoing at least three repeated early hemofiltration clotting filters in <6 h revealing HIT in ICU had a low probability score for HIT. Despite a 4T's score of three for the two patients and persistent early hemofiltration clotting filters, functional tests for HIT antibodies (heparin induced platelet activation assay and serotonin release assay) were positive, permitting the diagnosis of HIT in both patients. We suggest that the occurrence of repeated, rapid (within 6 h) hemofiltration filter clotting should score as two points for "Thrombosis" in the 4T's scoring system, thereby increasing the pretest probability for HIT in this clinical situation.
Repeated early hemofiltration filter clotting are real thrombotic events. Diagnosis of heparin-induced thrombocytopenia (HIT) in this setting in ICU remains difficult. We describe two cases of repeated early hemofiltration filters clotting in ICU and to evaluate their impact on the probability test 4T's score and diagnosis of HIT. Two patients undergoing at least three repeated early hemofiltration clotting filters in <6 h revealing HIT in ICU had a low probability score for HIT. Despite a 4T's score of three for the two patients and persistent early hemofiltration clotting filters, functional tests for HIT antibodies (heparin induced platelet activation assay and serotonin release assay) were positive, permitting the diagnosis of HIT in both patients. We suggest that the occurrence of repeated, rapid (within 6 h) hemofiltration filter clotting should score as two points for "Thrombosis" in the 4T's scoring system, thereby increasing the pretest probability for HIT in this clinical situation.
Related Concept Videos
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Venous Thrombosis III: Interprofessional Care
Hemodialysis II: Procedure and Complications
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Extracorporeal Removal of Drugs: Hemoperfusion and Hemofiltration
Continuous Renal Replacement Therapy

