Related Experiment Video
Updated: Apr 28, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Methodologic comparison of left ventricular stroke volumes in the early neonatal period by echocardiography
Hiroyuki Nagasawa1, Yoshinori Kohno, Yutaka Yamamoto
1Department of Neonatology, Gifu Prefectural General Medical Center, 4-6-1 Noisshiki, Gifu, 500-8717, Japan, hironag@ccn2.aitai.ne.jp.
Abstract:
Several methods for evaluating left ventricular stroke volume (SV) in neonates using echocardiography have been reported. However, no studies on methodologic comparison of SV with three-dimensional (3D) echocardiography are available. This is the first detailed report on a methodologic comparison of SV in the early neonatal period. The study group included 70 normal neonates (35 boys and 35 girls). An iE33 echocardiograph and Q-LAB supplied by Philips Electronics were used to examine and calculate volumes. Comparisons of SV were performed using Teichholz (T), the velocity time integral (VTI), Pombo (P), modified Simpson (MS), and 3D methods with normal neonates who had no persistent ductus arteriosus less than 7 days after birth. The mean SVs were 33.7 mL/m(2) (T), 30.6 mL/m(2) (VTI), 22.0 mL/m(2) (P), 17.5 mL/m(2) (3D), and 14.9 mL/m(2) (MS) using Haycock's formula of body surface area. The stroke volumes differed significantly depending on the different methods. The correlation coefficient was highest between the MS and 3D methods. The SVs of the T and VTI methods were significantly greater than those previously reported, and it seemed inappropriate to evaluate volumes in neonates. The 3D and MS methods were appropriate for measuring SV in neonates during the early neonatal period.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...