Yu Kawahara1, Takashi Nomura, Naoki Masaki
1Department of Cardiovascular Surgery, Yamagata Prefectural Central Hospital, Yamagata, Japan.
A 66-year-old man, presented with hematemesis and hemorrhagic shock, was transported to our institution. Computed tomographic examination suggested a pseudo-aneurysm formed by bleeding from aorto-esophageal fistula( AEF). We planned staged operations. At first, in an emergent operation, graft replacement of descending aorta, was performed under partial cardiopulmonary bypass, by left thoracotomy approach. AEF was 5 mm in diameter, and existed inside of normal-diameter and non-aneurysmal aortic intima. AEF orifice into pseudo-aneurysm was closed with aortic wall and was sutured tightly. Next day, gastrointestinal fiberscopy was performed, and penetrating ulcer was found at lower esophagus.To prevent infective complications, the 2nd operation, subtotal esophagectomy, cervical esophagostomy, gastrostomy and tube ileostomy were performed by right thoracotomy approach. Post- operative course was uneventful. Two months later, 3rd operation, cervical esophago-gastric anastomosis was performed, uneventfully. Two years and four months elapsed, and no evidences of infection and formation of pseudo-aneurysm were observed.
A 66-year-old man, presented with hematemesis and hemorrhagic shock, was transported to our institution. Computed tomographic examination suggested a pseudo-aneurysm formed by bleeding from aorto-esophageal fistula( AEF). We planned staged operations. At first, in an emergent operation, graft replacement of descending aorta, was performed under partial cardiopulmonary bypass, by left thoracotomy approach. AEF was 5 mm in diameter, and existed inside of normal-diameter and non-aneurysmal aortic intima. AEF orifice into pseudo-aneurysm was closed with aortic wall and was sutured tightly. Next day, gastrointestinal fiberscopy was performed, and penetrating ulcer was found at lower esophagus.To prevent infective complications, the 2nd operation, subtotal esophagectomy, cervical esophagostomy, gastrostomy and tube ileostomy were performed by right thoracotomy approach. Post- operative course was uneventful. Two months later, 3rd operation, cervical esophago-gastric anastomosis was performed, uneventfully. Two years and four months elapsed, and no evidences of infection and formation of pseudo-aneurysm were observed.
Related Concept Videos
Mitral Stenosis III: Medical Management
Aneurysm III: Interprofessional Care