Oesophageal pressure-flow metrics in relation to bolus volume, bolus consistency, and bolus perception
Related Experiment Video
Updated: Apr 28, 2026

Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
Taher I Omari1, Lucas Wauters2, Nathalie Rommel2
1Women's and Children's Health Network, Adelaide, Australia ; University of Adelaide, Adelaide, Australia.
Background:
The utility of combined oesophageal pressure-impedance recording has been enhanced by automation of data analysis.
Objective:
To understand how oesophageal function as measured by automated impedance manometry (AIM) pressure-flow analysis varies with bolus characteristics and subjective perception of bolus passage.
Methods:
Oesophageal pressure-impedance recordings of 5 and 10 ml liquid or viscous swallows and 2 and 4 cm solid swallows from 20 healthy control subjects (five male; 25-73 years) were analysed. Metrics indicative of bolus pressurization (intrabolus pressure and intrabolus pressure slope) were derived. Bolus flow resistance, the relationship between bolus pressurization and flow timing, was assessed using a pressure-flow index. Bolus retention was assessed using the ratio of nadir impedance to peak pressure impedance (impedance ratio). Subjective perception of bolus passage was assessed swallow by swallow.
Results:
Viscosity increased the bolus flow resistance and reduced bolus clearance. Responses to boluses of larger volume and more viscous consistency revealed a positive correlation between bolus pressurization and oesophageal peak pressure. Flow resistance was higher in subjects who perceived bolus hold up of solids.
Conclusions:
Bolus volume and bolus type alter oesophageal function and impact AIM analysis metrics descriptive of oesophageal function. Perception of bolus transit was associated with heightened bolus pressurization relative to bolus flow.
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Gastric Emptying
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...

