Related Experiment Video
Updated: Apr 28, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Diagnostic performance of low-dose computed tomography screening for lung cancer over five years
Giulia Veronesi1, Patrick Maisonneuve2, Lorenzo Spaggiari3
1Department of Thoracic Surgery, European Institute of Oncology, Milan, Italy.
Introduction:
Low-dose computed tomography (LD-CT) screening can reduce lung cancer mortality; however, it is essential to improve nodule management protocols. We analyze the performance of the diagnostic protocol of the Continuous Observation of SMOking Subjects single-center screening study, after long-term follow-up.
Methods:
Between 2004 and 2005, 5203 asymptomatic high-risk individuals (≥20 pack-years, aged 50 years or older) were enrolled to undergo annual LD-CT for 5 years. Nodules 5 mm or smaller underwent repeat LD-CT a year later. Nodules larger than 5.0 mm and 8.0 mm or smaller received LD-CT 3 to 6 months later. Nodules larger than 8.0 mm or growing underwent CT-positron emission tomography. True positives were any stage prevalent lung cancer, progressing nodules diagnosed at stage 1, localized multifocal cancer, or new nodules diagnosed at any stage. False negatives were progressing nodules diagnosed at stage >1. False positives were benign nodules resected surgically.
Results:
Compliance was 79% over 5 years; 175 primary lung cancers were detected (0.76% per year), 136 (77.7%) were N0M0 and three were interval cancers. Eleven second primary lung cancers were diagnosed. Resectability was 87.4%; postoperative mortality 0.6%. Recall was 6.4% overall, 10.1% at baseline. False negatives were 14 of 175 (8%). Protocol sensitivity was 158 of 175 (90%); specificity 4994 of 5028 (99.4%); positive predictive value was 158 of 187 (84.5%); and negative predictive value was 4994 of 5016 (99.7%). Twenty-nine of 204 (14.2%) benign lesions were diagnosed surgically. Five-year overall and cancer-specific survival were 78% (95% confidence interval, 72-84) and 82% (95% confidence interval, 76%-88%) respectively.
Conclusions:
The performance of the CT protocol was satisfactory with an acceptable number of benign lesions biopsied surgically, low recall rate, and good oncological outcomes. However, interval and advanced cancers, and misdiagnoses, need to be reduced, perhaps by risk modeling and use of serum markers.
More Related Videos
11:31Using Micro-computed Tomography for the Assessment of Tumor Development and Follow-up of Response to Treatment in a Mouse Model of Lung Cancer
Published on: May 20, 2016
10:26Author Spotlight: A 3D Digital Model for the Diagnosis and Treatment of Pulmonary Nodules
Published on: May 19, 2023
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...