Related Experiment Video
Updated: Apr 28, 2026

Determining Binding Affinity KD of Radiolabeled Antibodies to Immobilized Antigens
Published on: June 23, 2022
Determination of plasma protein binding of positron emission tomography radioligands by high-performance frontal
Nahid Amini1, Ryuji Nakao1, Magnus Schou2
1Karolinska Institutet, Department of Clinical Neuroscience, Center for Psychiatric Research, Stockholm, Sweden.
Abstract:
Positron emission tomography (PET) is an imaging technique based on the use of radioligands labeled with short lived radionuclides, such as (11)C (t½=20.4min) and (18)F (t½=109.8min), which as a consequence often requires rapid plasma protein binding analysis methods. In addition, PET radioligands can suffer from non-specific binding to the membrane when ultrafiltraion, which is the most commonly used method for measuring protein binding in PET, is employed. In this study a high-performance frontal analysis (HPFA) method based on incorporation of a gel filtration column (discovery(®) BIO GFC 100, 50mm×4.6mm, 5μm, 100Å) into a radio-LC system with phosphate buffered saline (PBS, pH 7.4) at a flow rate of 3ml/min as mobile phase was developed and investigated for four PET radioligands. The minimum injection volume (MIV) of plasma, which is a crucial factor in HPFA, was determined to be 200μl (human), 500μl (monkey), 700μl (human) and 1000μl (monkey) for these four radioligands. The MIV values increased as a higher fraction of the radioligand was present in the protein-free form. The protein binding results obtained were in good agreement with ultrafiltration and the method did not suffer from non-specific binding. The short analysis time (<12min) allowed multiple protein binding measurements during time course of a human [(11)C]PBR28 PET study.
More Related Videos
Related Concept Videos
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Drug Distribution: Plasma Protein Binding
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Physiological Pharmacokinetic Models: Assumption with Protein Binding