Ultrasound-guided lateral infraclavicular block evaluated by infrared thermography and distal skin temperature
S Asghar1, L H Lundstrøm, L S Bjerregaard
1Department of Anaesthesia and Intensive Care, Nordsjaellands Hospital, Hillerød, Denmark; Copenhagen University Hospital, Copenhagen, Denmark.
Background:
Brachial plexus blocks cause changes in hand and digit skin temperature. We investigated thermographic patterns after the lateral infraclavicular brachial plexus block. We hypothesised that a successful lateral infraclavicular block could be predicted by increased skin temperature of the 2nd and 5th digits.
Methods:
We performed an ultrasound-guided lateral infraclavicular block in 45 patients undergoing upper limb surgery. The contralateral hand served as control and we obtained infrared thermographic images of both hands before the block and during the following 30 min. We defined areas of interest on the hands and analysed mean skin temperature of each area.
Results:
Forty patients completed the study. Thirty blocks were successful, six were failures and four were partial failures. Four distinct patterns of skin temperature changes were revealed with highly significant changes in temperature, depending on block success. A simultaneous 1 °C ipsilateral increase in skin temperature of the 2nd and 5th digits predicted a successful block with a positive predictive value of 100%. A 5 °C difference in digit skin temperature compared with the contralateral hand had a positive predictive value of 96%, and a digit skin temperature ≤ 30 °C 30 min after performing the block had a predictive value of 100% for a failed block.
Conclusions:
Four different thermographic patterns were found. Simultaneous increases in skin temperature of both the 2nd and 5th digits predicted lateral infraclavicular block success with a positive predictive value of 100%. Digit skin temperature ≤ 30 °C 30 min after performing the block indicated block failure.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...