Nasal continuous positive airway pressure therapy in a non-tertiary neonatal unit: reduced need for up-transfers
Sai Kiran1, Srinivas Murki, Oleti Tejo Pratap
1Department of Pediatrics, Fernandez Hospital, Hyderabad, Andhra Pradesh, 500029, India.
Objective:
To evaluate the need for up-transfer after starting of nasal continuous positive airway pressure (n-CPAP) services in a Level II special newborn care unit (SNCU).
Methods:
Five hundred fifty infants admitted to Level II SNCU, 252 infants during one year prior to introduction of n-CPAP (retrospective data from case records and electronic data base) and 298 infants during one year after introduction of n-CPAP services (prospective data in predefined case reporting form) were evaluated in this before and after intervention trial. The primary outcome was proportion of infants needing up-transfers from Level II SNCU for any indication.
Results:
Baseline demographic data like birth weight, gestation and other perinatal factors were similar between the two epochs. Among the infants admitted to Level II SNCU, up-transfer for any reason was significantly higher in the pre-CPAP epoch compared with CPAP epoch (n = 93, 36 % vs. n = 74, 24.8 %, p = 0.002, OR 0.56, 95 % CI 0.38 to 0.83). However parent desired up-transfers were similar between the two epochs (n = 9, 3 % vs. n = 16, 5 %, p = 0.40). Introduction of n-CPAP treatment modality reduced up-transfers in subgroups of very low birth weight infants (VLBW) (n = 20, 74 % vs. n = 15, 37 %, p = 0.003) and also in preterm infants (n = 50, 54 % vs. n = 34, 32 %, p = 0.002).
Conclusions:
Introduction of n-CPAP services in a non-tertiary care neonatal unit, significantly reduced the need for up-transfers, especially in VLBW and preterm infants.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Suctioning the Nasopharyngeal Airway
Equipment Required
Cardiopulmonary Resuscitation II: ACLS Airway Management
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...