Related Experiment Video
Updated: Apr 27, 2026

Measuring Deformability and Red Cell Heterogeneity in Blood by Ektacytometry
Published on: January 12, 2018
Erythrocyte deformability responses to intermittent and continuous subhemolytic shear stress
Michael J Simmonds1, Nazli Atac2, Oguz K Baskurt2
1Heart Foundation Research Centre, Griffith Health Institute, Griffith University, Queensland, Australia.
Background:
Previous studies have demonstrated that red blood cells (RBC) either lyse or at least experience mechanical damage following prolonged exposure to high shear stress (≥100 Pa). Conversely, prolonged shear stress exposure within the physiological range (5-20 Pa, 300 s) was recently reported to improve RBC deformability. This study investigated the relationships between shear stress and RBC deformability to determine the breakpoint between beneficial vs. detrimental exposure to shear stress (i.e., "subhemolytic threshold"). A second aim of the study was to determine whether the frequency of intermittent application of shear stress influenced the subhemolytic threshold.
Methods:
RBC were exposed to various levels of shear stress (0-100 Pa) in a Couette type shearing system for 300 s. RBC deformability was then immediately measured via ektacytometry. Parallel experiments were conducted at the same shear stresses, except the application time differed while keeping constant the total exposure time: shear stress was applied either for 30 s and repeated 10 times (10×30 s) or applied for 15 s and repeated 20 times (20×15 s).
Results:
For a range of donors, the subhemolytic threshold with constant shear stress application was between 30-40 Pa. When physiological shear stress was applied in an intermittent manner, more frequent applications tended to improve (i.e., increase) RBC deformability. However, when supra-physiological shear stress was applied, both continuous and intermittent protocols damaged RBC. Changes of RBC mechanical behavior occurred without increases of hemoglobin in the suspending media, thus attesting to the absence of hemolysis.
Conclusion:
Shear stress has a biphasic effect on the mechanical properties of RBC, with the duration and rate of exposure appearing to have minimal impact on the subhemolytic threshold when compared with the magnitude of applied shear stress.
More Related Videos
Related Concept Videos
Lifecycle of Erythrocytes
The resident phagocytic macrophages deal with these damaged cells by engulfing them and separating their globin and heme groups....
Disorders of Erythrocytes
Erythrocyte disorders can be broadly categorized into two main types: anemic and polycythemic conditions.
A low oxygen-carrying capacity of the blood due to the loss, lower production, or destruction of erythrocytes is termed anemia. Hemorrhagic anemia, for example, occurs when bleeding from an external wound or internal ulcer reduces erythrocyte counts.
On the other...
Factors Affecting Erythropoiesis
Several factors influence the erythrocyte production rate, with tissue oxygen level being among the most critical. Intense exercise or high altitudes can cause tissue hypoxia, which triggers the kidneys to release more erythropoietin (EPO) into the bloodstream.
EPO then...
Shearing Strain
Structure and Function of Erythrocytes
The erythrocyte plasma membrane is associated with proteins such as spectrin, which forms a flexible cytoplasmic meshwork. This meshwork allows erythrocytes to twist, turn, become cup-shaped, and regain their biconcave shape as they pass through narrow capillaries. Additionally, erythrocytes can form...
Erythropoiesis