Additional MR contrast dosage for radiologists' diagnostic performance in detecting brain metastases: a systematic
Osamu Togao1, Akio Hiwatashi, Koji Yamashita
1Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan, togao@radiol.med.kyushu-u.ac.jp.
Purpose:
To evaluate the diagnostic performance of a double-dose administration of gadolinium for brain metastases at 3 T in a systematic observer test.
Materials And Methods:
Postcontrast MR images of 39 patients (total 104 metastases) were obtained by 3D T1-weighted sequences with both standard and cumulative double dose contrast administration. An observer test involving 9 radiologists (5 board-certified radiologists and 4 residents) was performed, and their diagnostic performance with the two doses was compared by means of sensitivity, false-positives, reading time, and a figure-of-merit.
Results:
Compared to the standard dose, the double dose showed higher sensitivity (P < 0.0001), higher false-positive/case (P < 0.05), longer reading time (P < 0.05), and higher figure-of-merit (P < 0.0001). Particularly in small lesions (< 5 mm), sensitivity with the double dose (61.5%, P < 0.0001) was approximately twice as high as that with the standard dose (29.5%). Artifacts and blood vessels were the most common imaging findings resulting in false-positives.
Conclusions:
The double dose improved detection for metastases smaller than 5 mm at 3 T and thus resulted in better diagnostic performance of radiologists. However, a higher dose might result in prolonged reading time and increased false-positives, presumably due to increased vessel signals and frequency of flow-related artifacts.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System IV: CMRI