Related Experiment Video
Updated: Apr 27, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants
Sudhindra Mahoorkar1, Anoop Jain2, Cauvery K3
1Professor, Department of Prosthodontics, HKE'S SN Institute of Dental Sciences & Research , Karnataka-585105, India .
Abstract:
An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.