Related Experiment Video
Updated: Apr 27, 2026

Collecting Sleep, Circadian, Fatigue, and Performance Data in Complex Operational Environments
Published on: August 8, 2019
A new method to make 24-hour urine collection more convenient: a validity study
Pooneh Nabavizadeh1, Shadi Ghadermarzi1, Mohammad Fakhri1
1School of Medicine, Shahid Beheshti University of Medical Science, Tehran, Iran.
A new urine collection device, which samples a small fraction of each void, accurately measures biomarkers compared to 24-hour collections. This automated method improves patient adherence for timed urine sampling.
Area of Science:
- Urology
- Biomedical Engineering
- Clinical Chemistry
Background:
- Timed 24-hour urine collection is crucial for diagnosing and monitoring various medical conditions.
- Conventional 24-hour urine collection methods can be burdensome for patients, potentially leading to poor adherence and inaccurate results.
- Novel approaches are needed to simplify urine collection and improve patient compliance.
Purpose of the Study:
- To evaluate a novel automated urine collection device that collects a fixed proportion (1/20th) of each void.
- To compare biomarker measurements (volume, creatinine, protein) obtained with the new device against conventional 24-hour urine collection.
- To assess patient adherence and convenience with the new automated urine collection method.
Main Methods:
- Forty healthy volunteers participated in the study.
- Each volunteer provided two 24-hour urine samples: one using the conventional method and one using the new automated device.
- Urine volume, creatinine, and protein levels were measured and compared between the two methods using Bland-Altman plots.
Main Results:
- A significant positive correlation (P < 0.001) was observed for all measured urine parameters between the novel device and the conventional method.
- Bland-Altman plots demonstrated a high degree of agreement for volume, creatinine, and protein measurements.
- A majority of participants reported the new automated urine collection device as more convenient.
Conclusions:
- The novel automated urine collection device accurately measures key urine biomarkers compared to traditional 24-hour sampling.
- Collecting a fixed proportion of each void significantly reduces the overall sample volume, enhancing patient adherence.
- This innovative device offers a more convenient and reliable alternative for timed urine collections.
Related Concept Videos
Urine Studies II: Urine Culture and Sensitivity Test
Urodynamic Studies: Uroflowmetry
Urine Studies I: Urinalysis
One-Compartment Open Model: Urinary Excretion Data and Determination of k
Bioavailability Study Design: Healthy Subjects Versus Patients
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...