Related Experiment Video
Updated: Apr 27, 2026

Spatial Measurements of Perfusion, Interstitial Fluid Pressure and Liposomes Accumulation in Solid Tumors
Published on: August 18, 2016
Automated volumetric analysis for comparison of oral sulfate solution (SUPREP) with established cathartic agents at
Peter Bannas1, Joshua Bakke, James L Patrick
1Department of Radiology, University of Wisconsin School of Medicine & Public Health, E3/311 Clinical Science Center, 600 Highland Ave., Madison, WI, 53792-3252, USA, pbannas@uwhealth.org.
Purpose:
To objectively compare residual colonic fluid volume and attenuation of oral sulfate solution (OSS) with four different established cathartic regimens using an automated volumetric software tool at CT colonography (CTC).
Methods:
This HIPAA-compliant study had institutional review board approval. Volumetric analysis of residual contrast-tagged colonic fluid was performed on CTC studies in 263 adults (mean age 60.1 years; 137M/126F) using an automated volumetric software tool. Twenty-three patients receiving 177 mL OSS (SUPREP; single-bottle purgation) were compared with 60 patients each receiving 45 mL sodium phosphate (NaP), 90 mL NaP (2× NaP), 592 mL (two bottles) magnesium citrate (MgC), and 4,000 mL polyethylene glycol (PEG). All patients received oral contrast cleansing after catharsis. Data were analyzed with unpaired t test with Welch correction and F test.
Results:
The mean volume of residual colonic fluid was less with OSS (125 ± 60 mL) than for established cathartic agents: 2× NaP (206 ± 125 mL, P < 0.0001), MgC (184 ± 125 mL, P < 0.01), PEG (166 ± 114 mL, P < 0.05), and NaP (165 ± 135 mL, P = 0.067). Variance of volumes was also significantly lower for OSS (range 28-251 mL) than for established agents (range 4-853 mL) (all P < 0.01). Mean fluid attenuation was higher with OSS (956 ± 168 HU) than for established agents (all P < 0.05): 2× NaP (455 ± 191 HU), MgC (691 ± 154 HU), NaP (779 ± 127 HU), and PEG (843 ± 193 HU).
Conclusions:
Automated volumetry allows rapid objective assessment of bowel preparation quality at CTC. Purgation with the novel oral sulfate solution (SUPREP) consistently resulted in less residual colonic fluid and higher fluid attenuation compared with established cathartic regimens.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
04:57Comparative Analysis of Automatic Fecal Analyzer versus Direct Wet Smear Microscopy for Detecting Parasitic Infections in Stool Samples
Published on: April 25, 2025
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Drugs Affecting GI Tract Motility: Other Laxatives
Osmotic or saline laxatives, like magnesium hydroxide or milk of...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures III: Video Capsule Endoscopy
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...
Imaging Studies VI: Voiding Cystourethrography and Cystography