Ionized calcium measurement in serum and plasma by ion selective electrodes: comparison of measured and calculated

Lena Jafri1, Aysha Habib Khan1, Saba Azeem2

  • 1Department of Pathology & Microbiology, Aga Khan University, Stadium Road, P.O. Box 3500, Karachi, 74800 Pakistan.

Related Concept Videos

Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
3.0K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.2K
Feedback Regulation of Calcium Concentration01:27

Feedback Regulation of Calcium Concentration

Calcium is an essential signaling molecule required for various cellular functions. Calcium pumps and ion channels on cell and organellar membranes, such as those on the endoplasmic reticulum (ER), regulate calcium concentrations inside the cell. They remain closed, keeping the cytosolic calcium levels low at a resting state.
Various transmembrane receptors, such as G protein-coupled receptors (GPCRs), elicit a response to extracellular signals by increasing cytosolic calcium. Activated GPCRs...
2.9K
EDTA: Direct, Back-, and Displacement Titration01:30

EDTA: Direct, Back-, and Displacement Titration

The EDTA titration types for metal ion analysis include direct titration, back-titration, and replacement titration.
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
6.5K