Related Experiment Video
Updated: Apr 27, 2026

Determining Viral Disinfection Efficacy of Hot Water Laundering
Published on: June 21, 2022
Analysis of isothiazolinone preservatives in polyvinyl alcohol cooling towels used in Japan
Tsuyoshi Kawakami1, Kazuo Isama, Yoshiaki Ikarashi
1a Division of Environmental Chemistry , National Institute of Health Sciences , Tokyo , Japan.
Abstract:
Recently, cases of contact dermatitis that were related to the use of polyvinyl alcohol (PVA) cooling towels containing isothiazolinone preservatives were reported in Japan. The aim of this investigation was to analyze the concentrations of five different isothiazolinone compounds present in PVA towels and to assess the effectiveness of washing in removing the preservatives from new towels prior to being used for the first time. Twenty-seven PVA towels were used in this study. Two groups (i.e., laboratory-simulation and volunteer) of washing experiments were conducted to evaluate the effect of washing procedures. Qualitative and quantitative analyses were performed by LC/MS/MS, which detected 2-methyl-4-isothiazolin-3-one (MI) and 5-chloro-2-methyl-4-isothaizolin-3-one (CMI) in 23 samples (MI: 0.29-154 μg g-wet(-1), CMI: 2.2-467 μg g-wet(-1)), 2-n-octyl-4-isothiazolin-3-one (OIT) in one sample (478 μg g-wet(-1)). The compounds 4,5-Dichloro-2-n-octyl-4-isothiazolin-3-one (2Cl-OIT) and 1,2-benzisothiazolin-3-one (BIT) were not detected in all samples. We confirmed the presence of residual MI, CMI, and OIT in the washed towels, and the residual-to-original content ratio of OIT was higher than that of MI and CMI in PVA towels, due to the higher hydrophobicity of OIT than MI and CMI. A concern has been raised about the occurrence of contact dermatitis being caused by the use of PVA towels. It is suggested that a detailed description of isothiazolinone preservatives in PVA towels and an effective washing procedure for the removal of these preservatives should be provided by the manufacturer. Further, alternative non-sensitizing preservatives might be considered for the manufacture of PVA cooling towels in the future.
More Related Videos
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Hand hygiene
Hand washing...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Chemical Agents for Microbial Control
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...

