Related Experiment Video
Updated: Apr 27, 2026

Micro-particle Image Velocimetry for Velocity Profile Measurements of Micro Blood Flows
Published on: April 25, 2013
Determination of whole blood and plasma viscosity by means of flow curve analysis
Peter Ruef1, Jutta Gehm, Lothar Gehm
1Department of Pediatrics, Clinic of Neonatology, University of Heidelberg, Germany. peter.ruef@t-online.de.
The LS300 viscometer permits automated measurements of viscosity at several shear rates of non-Newtonian fluids. We determined whole blood and plasma viscosity, aggregation, red blood cell deformability, and hematocrit of 66 healthy adults. The effects of the anticoagulants EDTA, heparin and citrate, and of centrifugation on blood viscosity (n=12) and red blood cell geometry (n=5) were investigated. With regard to the whole blood viscosity of adults, the best agreement was obtained by Casson's calculation compared to the methods of Ostwald, Bingham and Newton. The approximated flow curve of plasma showed only marginal differences between the method of Newton and Ostwald, whereas the latter gave the best quality of approximation. Centrifugation and the anticoagulants had a significant impact on whole blood viscosity and yield shear stress, whereas erythrocyte geometry remained unaffected. By linear regression of hematocrit with viscosity and yield shear stress, its impact on blood viscosity could be calculated in a hematocrit range of 0.32-0.50. Determination of whole blood viscosity should be performed in a standardized manner at several shear rates and without centrifugation of the blood samples.
The LS300 viscometer permits automated measurements of viscosity at several shear rates of non-Newtonian fluids. We determined whole blood and plasma viscosity, aggregation, red blood cell deformability, and hematocrit of 66 healthy adults. The effects of the anticoagulants EDTA, heparin and citrate, and of centrifugation on blood viscosity (n=12) and red blood cell geometry (n=5) were investigated. With regard to the whole blood viscosity of adults, the best agreement was obtained by Casson's calculation compared to the methods of Ostwald, Bingham and Newton. The approximated flow curve of plasma showed only marginal differences between the method of Newton and Ostwald, whereas the latter gave the best quality of approximation. Centrifugation and the anticoagulants had a significant impact on whole blood viscosity and yield shear stress, whereas erythrocyte geometry remained unaffected. By linear regression of hematocrit with viscosity and yield shear stress, its impact on blood viscosity could be calculated in a hematocrit range of 0.32-0.50. Determination of whole blood viscosity should be performed in a standardized manner at several shear rates and without centrifugation of the blood samples.
More Related Videos
07:30In Vitro Model of Physiological and Pathological Blood Flow with Application to Investigations of Vascular Cell Remodeling
Published on: November 3, 2015
10:25Microfluidic Flow Chambers Using Reconstituted Blood to Model Hemostasis and Platelet Transfusion In Vitro
Published on: March 19, 2016
Related Concept Videos
Applications of Integration to Find Blood Flow
Viscosity
Viscosity
The SI unit of viscosity is...
Steady, Laminar Flow in Circular Tubes
Laminar and Turbulent Flow
Viscosity of Fluid