Comparative effectiveness of two catheter locking solutions to reduce catheter-related bloodstream infection in hemodialysis patients
Related Experiment Video
Updated: Apr 27, 2026

A Protocol to Set Up Needle-Free Connector with Positive Displacement on Central Venous Catheter in Intensive Care Unit
Published on: July 13, 2019
Carol L Moore1, Anatole Besarab2, Marie Ajluni3
1Divisions of Nephrology and Hypertension, Department of Pharmacy Services, and manierski@wayne.edu.
Background And Objectives:
Infection is the second leading cause of death in hemodialysis patients. Catheter-related bloodstream infection and infection-related mortality have not improved in this population over the past two decades. This study evaluated the impact of a prophylactic antibiotic lock solution on the incidence of catheter-related bloodstream infection and mortality.
Design, Setting, Participants, & Measurements:
This prospective, multicenter, observational cohort study compared the effectiveness of two catheter locking solutions (gentamicin/citrate versus heparin) in 555 hemodialysis patients dialyzing with a tunneled cuffed catheter between 2008 and 2011. The groups were not mutually exclusive. Rates of catheter-related bloodstream infection and mortality hazards were compared between groups.
Results:
The study population (n=555 and 1350 catheters) had a median age of 62 years (interquartile range=41-83 years), with 50% men and 71% black. There were 427 patients evaluable in the heparin period (84,326 days) and 322 patients evaluable in the antibiotic lock period (71,192 days). Catheter-related bloodstream infection in the antibiotic lock period (0.45/1000 catheter days) was 73% lower than the heparin period (1.68/1000 catheter days; P=0.001). Antibiotic lock use was associated with a decreased risk of catheter-related bloodstream infection compared with heparin (risk ratio, 0.23; 95% confidence interval, 0.13 to 0.38 after multivariate adjustment). Cox proportional hazards modeling found that antibiotic lock was associated with a reduction in mortality (hazard ratio, 0.36; 95% confidence interval, 0.22 to 0.58 in unadjusted analyses; hazard ratio, 0.32; 95% confidence interval, 0.14 to 0.75 after multivariate adjustment). The rate of gentamicin-resistant organisms decreased (0.40/1000 person-years to 0.22/1000 person-years) in the antibiotic lock period (P=0.01).
Conclusions:
The results of this study show that the use of a prophylactic, gentamicin/citrate lock was associated with a substantial reduction in catheter-related bloodstream infection and is the first to report a survival advantage of antibiotic lock in a population at high risk of infection-related morbidity and mortality.
Related Concept Videos
Hemodialysis II: Procedure and Complications
Hemodialysis I: Introduction
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Peritoneal Dialysis II: Peritoneal Dialysis Systems and Complications
Hemodialysis III: Nursing Management
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...