Objective:
This article reports on a pilot study designed to collect dose data representative of current CT chest abdomen pelvis (CAP) practice in Scotland, make any immediately obvious interventions and to identify if the current UK diagnostic reference level (DRL) of 940 mGy cm is still appropriate. The aims are to identify if a Scotland-wide picture archiving and communication system (PACS)-based dose audit of a number of CT examinations is likely to have value in terms of optimization of patient doses and to comment on the significance of the results in terms of future optimization strategies.
Methods:
Dose audit of CT CAP examinations at 32 different scanner sites across Scotland using accepted data collection and analysis methods. The minimum sample size was 30.
Results:
RESULTS indicate that CT CAP doses are lower than those previously reported (median, 800 mGy cm, 75th percentile 840 mGy cm) but follow a distribution that is not in keeping with the concept of DRLs as presently understood or implemented.
Conclusion:
There is value in a PACS-based dose audit project to provide serial snapshots of patient doses as optimization efforts take place and to revise current knowledge about CT doses. In our opinion, the results call into question whether DRLs or the concept of "achievable dose" are suitable for devising optimization strategies once a certain degree of optimization has taken place.
Advances In Knowledge:
The results reported here suggest that it may be time to take a different approach to optimization, concentrating on tools that are more refined than the DRL, which may have become more of a compliance tool than an aid to optimization.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
06:52Positron Emission Tomography Using 64-Copper as a Tracer for the Study of Copper-Related Disorders
Published on: April 28, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT