Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

2.3K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

2.1K
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
2.1K
Atomic Spectroscopy: Absorption, Emission, and Fluorescence01:23

Atomic Spectroscopy: Absorption, Emission, and Fluorescence

3.1K
Atomic spectroscopy is a vital tool in elemental analysis, both qualitatively and quantitatively. It can be broadly divided into optical spectroscopy, mass spectroscopy, and X-ray spectroscopy methods. The optical spectroscopic methods are atomic absorption spectroscopy (AAS), atomic emission spectroscopy (AES), and atomic fluorescence spectroscopy (AFS). The first step in all three methods is atomization, where the solid, liquid, or solution-phase samples are converted into gas-phase atoms and...
3.1K
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

1.8K
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
1.8K
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview01:13

Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview

1.5K
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
1.5K
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

1.6K
Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
1.6K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A probe-free electrochemical immunosensor for methyl jasmonate based on ferrocene functionalized-carboxylated graphene-multi-walled carbon nanotube nanocomposites.

Talanta·2021
Same author

Long-Term Kidney Outcomes Following Dialysis-Treated Childhood Acute Kidney Injury: A Population-Based Cohort Study.

Journal of the American Society of Nephrology : JASN·2021
Same author

Synergistic regulation of methylation and SP1 on MAGE-D4 transcription in glioma.

American journal of translational research·2021
Same author

Incidence of Major Adverse Cardiovascular Events and Cardiac Mortality in High-Risk Kidney-Only and Simultaneous Pancreas-Kidney Transplant Recipients.

Kidney international reports·2021
Same author

The laterodorsal tegmentum-ventral tegmental area circuit controls depression-like behaviors by activating ErbB4 in DA neurons.

Molecular psychiatry·2021
Same author

Frequency splicing code-based Brillouin optical time domain collider for fast dynamic measurement.

Optics express·2021

Related Experiment Video

Updated: Apr 27, 2026

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
13:31

High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

Published on: December 22, 2015

14.6K

Absorption-free Bragg reflector using Zeeman sublevels in atomic vapor.

Zhongjie Chen, Bin Luo, Hong Guo

    Optics Express
    |July 1, 2014
    PubMed
    Summary

    Researchers propose a novel atomic scheme for an absorption-free Bragg reflector. This method utilizes Zeeman sublevels for practical laser power, offering a new approach to optical devices.

    Area of Science:

    • Atomic physics
    • Quantum optics
    • Solid-state physics

    Background:

    • Absorption-free Bragg reflectors are crucial for optical devices.
    • Existing methods often involve ions doped in crystals, posing limitations.

    Purpose of the Study:

    • To propose a new scheme for constructing an absorption-free Bragg reflector.
    • To utilize Zeeman sublevels of atoms for this purpose.
    • To achieve the reflector with practical laser power.

    Main Methods:

    • Theoretical proposal of a new scheme for Bragg reflector construction.
    • Utilizing Zeeman sublevels of atoms.
    • Simulating the proposal in a helium atom scheme.

    Main Results:

    More Related Videos

    Gradient Echo Quantum Memory in Warm Atomic Vapor
    10:00

    Gradient Echo Quantum Memory in Warm Atomic Vapor

    Published on: November 11, 2013

    13.1K
    Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
    13:44

    Simulation, Fabrication and Characterization of THz Metamaterial Absorbers

    Published on: December 27, 2012

    15.0K

    Related Experiment Videos

    Last Updated: Apr 27, 2026

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
    13:31

    High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis

    Published on: December 22, 2015

    14.6K
    Gradient Echo Quantum Memory in Warm Atomic Vapor
    10:00

    Gradient Echo Quantum Memory in Warm Atomic Vapor

    Published on: November 11, 2013

    13.1K
    Simulation, Fabrication and Characterization of THz Metamaterial Absorbers
    13:44

    Simulation, Fabrication and Characterization of THz Metamaterial Absorbers

    Published on: December 27, 2012

    15.0K
  • The proposed scheme constructs an absorption-free Bragg reflector.
  • The spatial period of the refractive index matches half the wavelength of the coupling light.
  • The method is feasible with practical laser power.
  • Conclusions:

    • The proposed atomic scheme offers a viable alternative for absorption-free Bragg reflectors.
    • The concept can be extended to other atomic systems like alkali earth atoms.