Evanescent excitation and collection of spontaneous Raman spectra using silicon nitride nanophotonic waveguides
Abstract:
We experimentally demonstrate the use of high contrast, CMOS-compatible integrated photonic waveguides for Raman spectroscopy. We also derive the dependence of collected Raman power with the waveguide parameters and experimentally verify the derived relations. Isopropyl alcohol (IPA) is evanescently excited and detected using single-mode silicon-nitride strip waveguides. We analyze the measured signal strength of pure IPA corresponding to an 819 cm⁻¹ Raman peak due to in-phase C-C-O stretch vibration for several waveguide lengths and deduce a pump power to Raman signal conversion efficiency on the waveguide to be at least 10⁻¹¹ per cm.
Related Concept Videos
Spontaneous and Induced Mutations
Emission Spectra
Spontaneity
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Excitation-Contraction Coupling in Skeletal Muscles
When an action...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...