Reliable coupling of orthodontic elements to mini-implants: An in-vitro study
Björn Ludwig1, Holger Zipprich2, Britta Gebel3
1Department of Orthodontics, University of Homburg / Saar Kirrberger Strasse 1, D- 66421 Homburg / Saar, Germany.
Journal of Orthodontic Science
|July 3, 2014
Summary
The best method for fixing rectangular wires in mini-implants is adhesive fixation with sandblasted and silanized wires. Mechanical fixation using crimped ligatures also offers reliable wire anchorage.
Area of Science:
- Orthodontics
- Biomaterials Engineering
- Dental Implantology
Background:
- Mini-implants are crucial in orthodontics for anchorage.
- Reliable fixation of wires to mini-implants is essential for effective treatment.
- Current methods for wire fixation require evaluation for mechanical strength and durability.
Purpose of the Study:
- To compare the reliability of mechanical and adhesive fixation methods for rectangular wires in mini-implants.
- To assess the influence of different surface preparation techniques on adhesive fixation strength.
- To evaluate the durability of fixation methods under simulated intraoral conditions.
Main Methods:
- Rectangular wires were fixed to mini-implants using either mechanical crimping or four adhesive preparation methods.
- Adhesive preparation involved untreated wire, ROCATEC-Pre, ROCATEC-PRE + Espe Sil, and ROCATEC-PRE + ROCATEC-PLUS + Espe Sil.
- Fixation integrity was tested using a universal testing machine after aging via 500 temperature cycles.
Main Results:
- The untreated wire with adhesive showed the lowest maximum load capacity (3 N and 10.8 N) and failed quickly during aging.
- The most effective adhesive fixation (Adh. 4: sandblasted and silanized) withstood the highest loads (average 43.3 N, 41.5 N after aging).
- Mechanical fixation with a crimped ligature demonstrated reliable strength, withstanding an average load of 38.7 N.
Conclusions:
- Adhesive fixation is most effective for rectangular wires in mini-implants when the wire is sandblasted and silanized prior to application.
- Mechanical coupling using a crimped ligature provides a reliable alternative for wire fixation in mini-implant systems.