Related Experiment Video
Updated: Apr 27, 2026

Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
Subcarinal ventilation-assisted Y-shaped stent insertion under local anesthesia for patients with complex
Purpose:
We aimed to report our preliminary results of subcarinal ventilation-assisted Y-shaped stent insertion under local anesthesia for patients with complex lower tracheal-carinal-main bronchial complex stenosis.
Materials And Methods:
Seven consecutive patients with lower tracheal-carinal-main bronchial complex stenosis underwent Y-shaped stent insertion under local anesthesia. During the procedure, subcarinal ventilation was performed using a 4 F angiographic catheter, and stent insertion was performed under the protection of ventilation. Data on technical success, clinical outcome, and follow-up were collected and analyzed.
Results:
Subcarinal ventilation-assisted Y-shaped stent insertion under local anesthesia was technically successful in all patients without any major procedure-related complications. Seven stents were inserted in seven patients. Respiratory function improved in all patients, with the Hugh-Jones classification of respiratory status improving from grade IV-V before stenting to grade I-II after stenting. During the follow-up, one patient experienced re-stenosis of the stent. Average survival time was 185.7 days (range, 96-285 days) after the stenting procedure.
Conclusion:
Subcarinal ventilation-assisted Y-shaped stent insertion under local anesthesia can be an effective, simple, and safe method for lower tracheal-carinal-main bronchial complex stenosis.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
03:58Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Related Concept Videos
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...