Objective:
To explore the relationship between Renying pulse (carotid) augmentation index (AI) and Cunkou pulse condition in different blood pressure groups, and the clinical significance of Renying and Cunkou pulse parameters to reflect vascular function.
Methods:
Eighty-six patients with essential hypertension (EH) and 52 individuals with normal blood pressure (control group) between September 2010 and January 2012 were included in this study. Renying pulse AI was examined by a new diagnostic tool (ALOKA ProSound Alpha 10)--wave intensity (WI) that is calculated as the product of the derivatives of the simultaneously recorded blood pressure changes (dP/dt) and blood-flow-velocity changes (dU/dt), while Cunkou pulse condition was detected by DDMX-100 Pulse Apparatus in both EH and control groups. A multifactorial correlation analysis was performed for data analysis.
Results:
After adjusting for potential confounding variables, in the EH group, AI was positively correlated with t5, w2/t (r(t5) = 0.225, P < 0.05; r(w2/t) = 0.230, P < 0.05) and negatively correlated with h5, h5/h1 and w2 (r(h5) = -0.393, P < 0.01; r(h5)/h1) = -0.444, P < 0.01; r(w2) = -0.389, P < 0.01). In the control group, AI was positively correlated with t3, t4, t5 and w1 (r(t3) = 0.595, P < 0.01; r(t4) = 0.292, P < 0.05; r(t5) = 0.318, P < 0.05; r(w1) = 0.541, P < 0.01) and negatively correlated with h1, h2, h3, Ad and A (r(h1) = -0.368, P < 0.05; r(h2) = -0.330, P < 0.05; r(h3) = -0.327, P < 0.05; rAd = -0.322, P < 0.05; rA = -0.410, P < 0.01). In the total sample group (EH plus control group, n = 138), AI was positively correlated with t, t5, w1 and w2t (r(t) = 0.257, P < 0.01; r(t5) = 0.266, P < 0.01; r(w1) = 0.184, P < 0.05; r(w2/t) = 0.210, P < 0.05) and negatively correlated with h5, h5/h1, w2 and Ad (r(h5) = -0.230, P < 0.01; r(h5/h1) = -0.218, P < 0.05; r(w2) = -0.267, P < 0.01; rAd = -0.246, P < 0.01). Multiple linear regression analysis was carried out to model the relationship (F = 7.887, P < 0.001).
Conclusion:
Renying pulse AI can effectively predict arterial stiffness in synchrony with the manifestations of Cunkou pulse in elderly patients with hypertension. Cunkou pulse apparatus is a valuable tool for evaluating AI in clinical practice. The close correlations reported above reflect the holistic concept of Traditional Chinese Medicine.
More Related Videos
05:51Measuring the Carotid to Femoral Pulse Wave Velocity Cf-PWV to Evaluate Arterial Stiffness
Published on: May 3, 2018
03:05Influence of Emotional Factors on the Efficacy of Acupuncture Treatment for Overweight Complicated with Hyperlipidemia: A Retrospective Cohort Study
Published on: November 21, 2025
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Regulation of Pulse