Related Experiment Video
Updated: Apr 27, 2026

Laser Doppler Perfusion Imaging in the Mouse Hindlimb
Published on: April 18, 2021
High-Volume Hydrodissection: Assessment of Deep Inferior Epigastric Perforator Flap Perfusion Using Laser Doppler
Paolo Maria Fanzio1, Ming-Huei Cheng, Ivan Samcam
1From the *Division of Reconstructive Microsurgery, Department of Plastic and Reconstructive Surgery, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan, Taiwan; †Division of Plastic and Reconstructive Surgery, Department of Surgery, University of Florida Health System, University of Florida Medical School, Gainesville, FL; ‡Department of Plastic Surgery, UPMC Medical Center, University of Pittsburgh, Pittsburgh, PA; and §Division of Plastic and Reconstructive Surgery, Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
Abstract:
High-volume hydrodissection of intramuscular perforators of deep inferior epigastric perforator (DIEP) flaps in Sprague-Dawley rats has previously demonstrated a significant reduction in dissection time while simultaneously increasing the safety of dissection. However, increasing volumes of fluid injected into the closed rectus compartment may have adverse consequences on perfusion to the overlying flap. A prospective experimental animal study was performed to define a safe upper limit of volume injection for high-volume hydrodissection. Eight Sprague-Dawley rats underwent bilateral "DIEP" flap dissections with varying volumes of fluid (1, 3, 6, and 9 mL) injected into the study side. The primary outcome measurement was overlying tissue perfusion, measured using laser Doppler imaging, at 6 separate time points during the flap harvest. Although no significant difference in perfusion was noted between study and control sides despite increasing volumes of injection, a trend toward significant altered perfusion was noted immediately after injection in the 9-mL study group. Six milliliters is defined as the safe upper limit volume of injection into the closed rectus compartment without significantly altering overlying flap perfusion in our Sprague-Dawley rats. Using volumetric analysis, these data translate to 425 mL as the safe upper limit for high-volume hydrodissection for a single average sized human rectus sheath during DIEP flap harvesting. The mechanical and potentially pharmacologic implications of these data in humans remain to be seen.
More Related Videos
07:57An Experimental Human DIEP Flap Model to Investigate Preservation Strategies for Vascularized Composite Allografts and Free Flaps
Published on: December 5, 2025
11:12In situ Transverse Rectus Abdominis Myocutaneous Flap: A Rat Model of Myocutaneous Ischemia Reperfusion Injury
Published on: June 8, 2013