Related Experiment Video
Updated: Apr 27, 2026

Diagnosis of Neoplasia in Barrett’s Esophagus using Vital-dye Enhanced Fluorescence Imaging
Published on: May 11, 2014
Endoscopists with low adenoma detection rates benefit from high-definition endoscopy
Elisabeth Waldmann1, Martha Britto-Arias, Irina Gessl
1Division of Gastroenterology and Hepatology, Department of Internal Medicine III, Medical University of Vienna, Waehringer Guertel 18-20, 1090, Vienna, Austria, elisabeth.waldmann@meduniwien.ac.at.
Background:
An endoscopists adenoma detection rate (ADR) of less than 20 % correlates with high risk for occurrence of interval cancer. The impact of high-definition (HD) imaging on the ADR is discussed controversially. We aimed to investigate whether detection rates of individual endoscopists increase within 1 year before and 1 year after the switch from standard to HD endoscopy.
Methods:
This cohort study analyzed 6,330 screening colonoscopies (2,968 with standard and 3,362 with HD) performed by 42 endoscopists between November 2007 and March 2013 within a nationwide quality assurance program for screening colonoscopy.
Results:
The ADR of endoscopists with a low ADR (<20 %) increased significantly higher (from 11.8 to 18.1 %, p = 0.003) than of those with a high ADR (≥ 20 %) (from 28.6 to 30.7 %, p = 0.439) after switch from standard to HD colonoscopes (p = 0.0076). The proportion of endoscopists with an ADR < 20 % decreased from 45 to 42.9 % (p = 0.593). There was no significant increase in age- and sex-adjusted detection rates of adenomas (20.2 vs 23.7 %; p = 0.089), advanced adenomas (4.7 vs 5.5 %; p = 0.479), flat adenomas (2.7 vs 3.1 %; p = 0.515), polyps (38.8 vs 41.5 %; p = 0.305), proximal polyps (18.5 vs 20 %; p = 0.469) and hyperplastic polyps (15 vs 17.2 %; p = 0.243) of endoscopists after switch to HD colonoscopes. There was no difference in detection rates of flat polyps (5.5 vs 5.5 %; p = 0.987).
Conclusions:
The use of HD scopes is associated with marginal improvement in adenoma detection rates limited to those endoscopists with low adenoma detection rates prior to its introduction.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):