IUPAC-consistent approach to the limit of detection in partial least-squares calibration
Franco Allegrini1, Alejandro C Olivieri
1Departamento de Química Analítica, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Instituto de Química de Rosario (IQUIR-CONICET) , Suipacha 531, Rosario S2002LRK, Argentina.
Abstract:
There is currently no well-defined procedure for providing the limit of detection (LOD) in multivariate calibration. Defining an estimator for the LOD in this scenario has shown to be more complex than intuitively extending the traditional univariate definition. For these reasons, although many attempts have been made to arrive at a reasonable convention, additional effort is required to achieve full agreement between the univariate and multivariate LOD definitions. In this work, a novel approach is presented to estimate the LOD in partial least-squares (PLS) calibration. Instead of a single LOD value, an interval of LODs is provided, which depends on the variation of the background composition in the calibration space. This is in contrast with previously proposed univariate extensions of the LOD concept. With the present definition, the LOD interval becomes a parameter characterizing the overall PLS calibration model, and not each test sample in particular, as has been proposed in the past. The new approach takes into account IUPAC official recommendations, and also the latest developments in error-in-variables theory for PLS calibration. Both simulated and real analytical systems have been studied for illustrating the properties of the new LOD concept.
More Related Videos
Related Concept Videos
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...