Related Experiment Video
Updated: Apr 27, 2026

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Analysis of a data-fusion system for continuous vital sign monitoring in an emergency department
Sarah J Wilson1, David Wong, Richard M Pullinger
1aEmergency Department, Oxford University Hospitals NHS Trust, Oxford bDepartment of Engineering Science, Institute of Biomedical Engineering, University of Oxford, Oxford cEmergency Department, Heatherwood and Wexham Park Hospitals NHS Foundation Trust, Slough, UK.
Objective:
The aim of the study was to evaluate the ability of a data-fusion patient status index (PSI) to detect patient deterioration in the emergency department (ED) in comparison with track-and-trigger (T&T).
Materials And Methods:
A single-centre observational cohort study was conducted in a medium-sized teaching hospital ED. Vital sign data and any documented T&T scores (paper T&T) were collected from adults attending the resuscitation room, majors or observation ward. For each set of vital signs, we retrospectively calculated T&T (eT&T). PSI was calculated retrospectively from the continuous vital sign data using a statistical model of normality. Clinical notes were examined to identify 'escalation' events, and the numbers of these escalations identified by paper T&T, eT&T and PSI were retrospectively calculated.
Results:
Data from 472 patient episodes were examined. A total of 20 patients had PSI data at the time of an escalation related to vital sign abnormalities that occurred during their ED stay (vs. on arrival). Only four patient events were detected at the time by paper T&T. In all, 17 were detected retrospectively by eT&T and 15 by PSI. PSI had a calculated false-alert rate of 1.13 alerts/bed-day.
Conclusion:
Electronic data capture offers opportunities for increased detection of deteriorating patients in a busy clinical environment compared with paper charts. Sample size in this study is insufficient to determine which electronic method (eT&T or PSI) offers superior detection of the need for escalation.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Holter Monitor: 24-Hour Monitoring
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

