Related Experiment Video
Updated: Apr 27, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Relative myocardial blood flow by dynamic computed tomographic perfusion imaging predicts hemodynamic significance of
Atsushi K Kono1, Adriaan Coenen, Marisa Lubbers
1From the Departments of *Radiology, and †Cardiology, Erasmus Medical Center, Rotterdam, the Netherlands.
Objectives:
Quantitative myocardial perfusion imaging by computed tomography (CT) was recently introduced to calculate myocardial blood flow (MBF). Because absolute MBF thresholds may be affected by technique, methodology, and the microvasculature, we investigated whether a relative measure of MBF improves accuracy to identify hemodynamically significant coronary stenosis.
Materials And Methods:
In this prospective study, 42 patients (mean [SD] age, 62.3[8.7] years; 8 women) with suspected or known coronary disease underwent dynamic CT myocardial perfusion imaging using adenosine vasodilation, before invasive angiography (coronary angiography) with fractional flow reserve (FFR). Within each myocardial territory MBF, the MBF relative to remote myocardium (MBFratio) was calculated and compared with coronary angiography and FFR.
Results:
Of the 91 vessels interrogated by FFR (median, 0.81; interquartile range, 0.73-0.94), 45 vessels (49%) had an FFR value lower than 0.8 and were considered hemodynamically significant. Hyperemic MBF was lower in ischemic territories: 75.6 ± 22.5 mL per 100 mL/min versus 98.3 ± 23.1 mL per 100 mL/min (P < 0.0001). The MBFratio correlated better with FFR (P = 0.76) than the absolute MBF did (P = 0.52). Receiver operating curve analysis showed better discrimination by MBFratio: area under the curve of 0.85 versus 0.75 (P = 0.02). The MBF of remote myocardium varied between 60.7 and 167.2 mL per 100 mL/min and was lower in patients without heart rate acceleration (P = 0.0035).
Conclusions:
The MBFratio seems to better identify hemodynamically significant coronary artery disease than does the absolute MBF determined by dynamic CT perfusion imaging. This may be caused by microvascular status or related to the methodology.
More Related Videos
05:07Author Spotlight: Improved Localization and Monitoring of Coronary Flow Reserve Using Modified PLAX View in Mice
Published on: August 25, 2023
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System V: CT