Robustness, specificity, and reliability of an in-ear pulse oximetric sensor in surgical patients
Abstract:
For many years, pulse oximetry has been widely used in the clinical environment for a reliable monitoring of oxygen saturation ( SpO2) and heart rate. But since common sensors are mainly placed to peripheral body parts as finger or earlobe, it is still highly susceptible to reduced peripheral perfusion, e.g., due to centralization. Therefore, a novel in-ear pulse oximetric sensor (placed against the tragus) was presented in a prior work which is deemed to be independent from perfusion fluctuations due to its proximity to the trunk. Having demonstrated the feasibility of in-ear SpO2 measurement with reliable specificity in a laboratory setting, we now report results from a study on in-ear SpO2 in a clinical setting. For this, trials were performed on 29 adult patients undergoing surgery. In-ear SpO2 data are compared with SaO2 data obtained by blood gas analysis, and with three reference pulse oximeters applied to the finger, ear lobe, and forehead. In addition, we derived an SpO2-independent perfusion index by means of the wavelengths used. The feasibility and robustness of in-ear SpO2 measurement is demonstrated under challenging clinical conditions. SpO2 shows good accordance with SaO2, a high level of comparability with the reference pulse oximeters, and was significantly improved by introducing a new algorithm for artifact reduction. The perfusion index also shows a good correlation with the reference data.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Pulse
The pulse serves as a clinical...