Cerebral arterial inflow assessment with 18F-FDG PET: methodology and feasibility
Jennifer Benathan-Tordjmann1, Pascal Bailly1, Marc-Etienne Meyer2
1Service de médecine nucléaire et de traitement de l'image médicale, Centre Hospitalier Universitaire d'Amiens, Amiens, France.
Positron emission tomography (PET) with 18fluorodeoxyglucose (18F-FDG) is increasingly used in neurology. The measurement of cerebral arterial inflow (QA) using 18F-FDG complements the information provided by standard brain PET imaging. Here, injections were performed after the beginning of dynamic acquisitions and the time to arrival (t0) of activity in the gantry's field of view was computed. We performed a phantom study using a branched tube (internal diameter: 4mm) and a 18F-FDG solution injected at 240 mL/min. Data processing consisted of (i) reconstruction of the first 3s after t0, (ii) vascular signal enhancement and (iii) clustering. This method was then applied in four subjects. We measured the volumes of the tubes or vascular trees and calculated the corresponding flows. In the phantom, the flow was calculated to be 244.2 mL/min. In each subject, our QA value was compared with that obtained by quantitative cine-phase contrast magnetic resonance imaging; the mean QA value of 581.4±217.5 mL/min calculated with 18F-FDG PET was consistent with the mean value of 593.3±205.8 mL/min calculated with quantitative cine-phase contrast magnetic resonance imaging. Our 18F-FDG PET method constitutes a novel, fully automatic means of measuring QA.
Positron emission tomography (PET) with 18fluorodeoxyglucose (18F-FDG) is increasingly used in neurology. The measurement of cerebral arterial inflow (QA) using 18F-FDG complements the information provided by standard brain PET imaging. Here, injections were performed after the beginning of dynamic acquisitions and the time to arrival (t0) of activity in the gantry's field of view was computed. We performed a phantom study using a branched tube (internal diameter: 4mm) and a 18F-FDG solution injected at 240 mL/min. Data processing consisted of (i) reconstruction of the first 3s after t0, (ii) vascular signal enhancement and (iii) clustering. This method was then applied in four subjects. We measured the volumes of the tubes or vascular trees and calculated the corresponding flows. In the phantom, the flow was calculated to be 244.2 mL/min. In each subject, our QA value was compared with that obtained by quantitative cine-phase contrast magnetic resonance imaging; the mean QA value of 581.4±217.5 mL/min calculated with 18F-FDG PET was consistent with the mean value of 593.3±205.8 mL/min calculated with quantitative cine-phase contrast magnetic resonance imaging. Our 18F-FDG PET method constitutes a novel, fully automatic means of measuring QA.
More Related Videos
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)