Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
Published on: June 21, 2024
Magnetic resonance assessment of pulmonary (QP) to systemic (QS) flows using 4D phase-contrast imaging: pilot study
Kate Hanneman1, Milani Sivagnanam1, Elsie T Nguyen1
1Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto General Hospital, University Health Network, University of Toronto, 585 University Ave, Toronto, Ontario M5G 2N2, Canada.
Rationale And Objectives:
To investigate four-dimensional (4D) phase-contrast (PC) magnetic resonance (MR) in the evaluation of intracardiac shunts by simultaneous assessment of pulmonary (QP) and systemic (QS) flows in a pilot study and to compare results to through-plane two-dimensional (2D) PC MR.
Materials And Methods:
Institutional review board approval and written informed consent were obtained. Nineteen patients with suspected intracardiac shunts underwent cardiac MR at 1.5T. Assessments of QP and QS were performed using free-breathing retrospectively gated 2D PC gradient recalled echo (GRE; 1.6 × 1.6 × 5 mm(3)) imaging with one-dimensional through-plane velocity encoding gradient (venc = 150 cm/s) in consecutive measurements for the main pulmonary artery (MPA) and ascending aorta (AA), respectively. A prospectively triggered 4D PC GRE technique (2.4 × 1.8 × 3 mm(3)) with three orthogonal venc directions was also used with volume coverage of both MPA and AA.
Results:
QP and QS assessed by 4D PC correlated with 2D PC acquisitions (r = 0.92 and r = 0.67 respectively; P < .0001 for both) but demonstrated significant underestimation of individual flow volumes (-21.9 ± 12.2 mL; P < .0001 and -10.7 ± 13.1 mL; P = .0023, respectively). Calculated QP:QS ratios demonstrated high correlation (r = 0.78; P < .0001) and no significant differences between 4D PC and 2D PC acquisitions (-0.09 ± 0.24, P = .14). Image acquisition times for 2D PC assessment of QP and QS were 2.98 ± 0.52 and 2.84 ± 0.50 minutes, respectively (P = .038), whereas time to acquire 4D PC images was significantly longer, 18.75 ± 4.58 minutes (P < .001).
Conclusions:
Four-dimensional PC MR imaging allows for accurate assessment of QP:QS ratios in the evaluation of intracardiac shunts while absolute flow volumes demonstrate offsets. Further refinement of the technique with improvement in acquisition times may be required before widespread clinical implementation.
Related Concept Videos
Magnetic Resonance Imaging
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies for Cardiovascular System IV: CMRI