Abstract:
Current clinical guidelines recommend capnography as one of the best non-invasive methods to assess adequacy of ventilation in the non-intubated patient. Alveolar hypoventilation or respiratory depression is a serious event that occurs in a variety of clinical settings where patients receive sedatives and opioids. With the large number of procedures performed outside the operating room under the effects of sedatives and the increased use of patient-controlled analgesia, the need for capnography for monitoring has dramatically increased. Despite the succesful use of capnography to monitor ventilation in the operating room over several decades, other clinical areas have been very slow adapters of the technology and still rely heavily upon pulse oximetry to detect hypoventilation. This article reviews the most current evidence for using capnography in the non-intubated patient and summarizes the results of outcome measures reported in recent clinical trials. Capnography should be routinely used for non-intubated patients at risk for respiratory depression, in particular those receiving supplemental oxygen.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Respiratory Failure-III
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques