Andrea Sartore1, Floriana Zennaro, Rubina Banco
1Department of Obstetrics and Gynecology, Institute for Maternal and Child Health, IRCCS Burlo Garofolo, Via dell'Istria 65/1, 34137, Trieste, Italy, andrea.sartore@burlo.trieste.it.
Abstract:
Serious complications associated with surgical mesh for transvaginal repair of POP, as infections, vaginal mesh exposure, painful mesh shrinkage and dyspareunia, are not rare. A 48-year-old woman underwent the Perigee procedure because of a stage 3 anterior wall prolapse. Eleven months after surgery, the patient became suddenly unable to walk because of a strong pain to the left thigh root after running. The MRI revealed an external obturator left muscle hyperintensity consistent with muscular oedema; the patient was treated with oral corticosteroids with a complete resolution of the pain. We could hypothesize that the posterior arm of the mesh caused a laceration of the muscles of the obturator space with consequent oedema and pain. The use of the meshes in prolapse surgery can cause unexpected long-term complications.