Related Experiment Video
Updated: Apr 27, 2026

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Trend of change in retentive force for bar attachments with different materials
Marie Saito1, Manabu Kanazawa2, Hidekazu Takahashi3
1Graduate student, Complete Denture Prosthodontics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo, Japan.
Statement Of Problem:
Attachment wear can decrease the retentive force of 2-implant overdentures (2-IODs).
Purpose:
The purpose of this in vitro study was to investigate the trend of change in retentive force for 6 different bar attachments during dislodgement.
Material And Methods:
Round and Dolder bars were made of platinum-added gold alloy (PGA), cobalt chromium alloy (Co-Cr), and commercially pure titanium grade IV (Ti). Clips were made of PGA. Retentive force was measured during 7200 dislodging cycles. Simple linear regression analysis was performed in order to investigate the relationship between number of cycles and retentive force (P<.05). Subsequently, wear debris was analyzed, and the surface of the attachments was observed.
Results:
The retentive force of the Co-Cr round bar attachment (CoCr-R) increased from 57.5 N to 68.3 N and the Ti round bar attachment (Ti-R) from 54.8 N to 59.7 N. However, the retentive force of the PGA round bar attachment (PGA-R) decreased from 69.3 N to 64.0 N. A positive relationship was found between the number of cycles and the retentive force of both CoCr-R and Ti-R. The composition of the wear debris was almost the same as for PGA. For the Dolder bar attachment, no changes were seen in retentive force (between 7.0 N to 12.0 N).
Conclusions:
For the round bar attachment, the PGA clip and PGA bar showed wear. The retentive force of PGA-R slightly decreased. The retentive force of CoCr-R and Ti-R tended to increase. For the Dolder bar attachment, all 3 types of bar attachment showed no wear.
Related Concept Videos
Hooke's Law
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Temperature Dependent Deformation
Plastic Behavior
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Stress-Strain Diagram - Brittle Materials