Related Experiment Video
Updated: Apr 27, 2026

Nerve Ultrasound Protocol to Detect Dysimmune Neuropathies
Published on: October 7, 2021
Sensory and motor nerve conduction velocities following therapeutic ultrasound
Abstract:
Nineteen healthy volunteers each received six, five-minute ultrasound treatments at sonation intensities of 0.0, 0.5, 1.0, 1.5, 2.0 and 2.5 W/cm(2), applied along the proximal forearm segment of the ulnar nerve, over an area of approximately 4.5 times the area of the ultasound application head. Sensory and motor nerve conduction velocities responded similarly, but not identically to ultrasound. All clinical intensities, with the exception of 0.5 W/cm(2) (p <0.10), were associated with significantly increased velocities. Subcutaneous tissue temperatures were directly related to sonation intensity, although significantly increased temperatures were not observed until 1.5 W/cm(2) intensity was used. The effectiveness of clinical applications of ultrasound in pain relief cannot be attributed to a decrease in nerve conduction velocity of the faster conducting A-fibers, which are evaluated using standard nerve conduction techniques.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Local Anesthetics: Differential Sensitivity of Nerve Fibers
Motor Unit Stimulation
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
Imaging Studies II: Ultrasonography