Carbon film coating of abutment surfaces: effect on the abutment screw removal torque
Pedro Henrique Corazza1, Alecsandro de Moura Silva, José Renato Cavalcanti Queiroz
1*PhD Student, Department of Dental Materials and Prosthodontics, Institute for Science and Technology at São Jose dos Campos, São Paulo State University, São José dos Campos, Brazil. †Collaborating Professor, Department of Physics, Technologic Institute of Aeronautics, São José dos Campos, Brazil. ‡Postdoctoral Student, Department of Dental Materials and Prosthodontics, São Paulo University, São Paulo, Brazil. §Professor, Department of Dental Materials and Prosthodontics, Institute for Science and Technology at São Jose dos Campos, São Paulo State University, São José dos Campos, Brazil. ‖Adjunct Professor, Division of Prosthodontics, Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Brazil.
Purpose:
To evaluate the effect of diamond-like carbon (DLC) coating of prefabricated implant abutment on screw removal torque (RT) before and after mechanical cycling (MC).
Materials And Methods:
Fifty-four abutments for external-hex implants were divided among 6 groups (n = 9): S, straight abutment (control); SC, straight coated abutment; SCy, straight abutment and MC; SCCy, straight coated abutment and MC; ACy, angled abutment and MC; and ACCy, angled coated abutment and MC. The abutments were attached to the implants by a titanium screw. RT values were measured and registered. Data (in Newton centimeter) were analyzed with analysis of variance and Dunnet test (α = 0.05).
Results:
RT values were significantly affected by MC (P = 0.001) and the interaction between DLC coating and MC (P = 0.038). SCy and ACy showed the lowest RT values, statistically different from the control. The abutment coated groups had no statistical difference compared with the control. Scanning electron microscopy analysis showed DLC film with a thickness of 3 μm uniformly coating the hexagonal abutment.
Conclusion:
DLC film deposited on the abutment can be used as an alternative procedure to reduce abutment screw loosening.
More Related Videos
Related Concept Videos
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Upward Impending Motion
To better comprehend how a screw jack functions, consider the completely unraveled thread as a block in contact with the...