Related Experiment Video
Updated: Apr 27, 2026

A Guide to Concentration Alternating Frequency Response Analysis of Fuel Cells
Published on: December 11, 2019
Monitoring the oxygen transfer efficiency of full-scale aeration systems: investigation method and experimental
Riccardo Gori1, Alice Balducci1, Cecilia Caretti1
1Department of Civil and Environmental Engineering, University of Florence, Via S.Marta, 3 - 50139 Florence, Italy
Abstract:
This paper reports the results of a series of off-gas tests aimed at monitoring the evolution of the oxygen transfer efficiency in an urban wastewater treatment plant (3,500 population equivalent) located in Tuscany (Italy). The tests were conducted over a 2-year period starting with the testing of the aeration system. It was found that in the absence of membrane-panel cleaning operations, the oxygen transfer efficiency under standard conditions in process water (αSOTE) dropped from 18 to 9.5% in 2 years. This gives rise to a 40% increase in the wastewater treatment plant annual energy costs. The on-site chemical cleaning of the diffusers allowed for an almost total recovery of the transfer efficiency (αSOTE equal to 16%). The use of the off-gas method for monitoring the oxygen transfer efficiency over time is therefore essential for enabling correct planning of the cleaning operations of the diffusers and for cutting the energy consumption and operating costs of the aeration system.
More Related Videos
Related Concept Videos
Bioreactor Controls-I
Bioreactor Controls-II
Bioreactor Design and Operational System
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...